ELECTRICAL:
Spec sheets are required for all food related equipment. Spec sheets must be attached to the plan set.
All equipment used in food establishments must be certified by an NSF or other ANSI accredited certification
program. Electrical equipment must be UL listed or have other approved safety certification. All equipment must be
commercial – no residential equipment is allowed.
A floor plan indicating placement of equipment is required for plan review purposes.
All equipment shall be constructed of approved material and be easily cleanable.
Table mounted equipment must be sealed to the table or counter OR elevated on legs to provide 4” clearance
between equipment and table or counter to facilitate cleaning.
Floor mounted equipment should be mounted on castors or wheels whenever possible to facilitate cleaning.
Floor mounted equipment not mounted on wheels or castors should be sealed to the floor around the entire
perimeter of the equipment. The sealing compound should be pliable, retain elasticity and provide a waterproof and
vermin proof joint.
Equipment elevated on legs must provide at least a 6” clearance between the floor and the equipment.
Equipment not easily moveable by one person must have adequate space between and behind equipment to be
sufficient to permit cleaning.
Equipment butted together or having spreader plates, the resulting joins must prohibit the accumulation of debris.
Equipment butted against a wall must be sealed or sealed to the wall to prevent liquid waste, dust and debris from
collecting between the wall and the equipment.
A minimum two section storage facility is required to store toxic items
such as cleaners, sanitizer, insecticides and rodenticides. Illustrate
location and the design of the storage unit.
EXHAUST HOODS:
The Fire Marshal determines if and when an exhaust hood is required.
Type I Hoods are required over cooking equipment that produces
grease, smoke, excessive steam, heat, condensation, particulate
matter, odors or create indoor sanitation and indoor air quality
problems.
Type II Hoods shall be installed over equipment that produces steam,
heat, mists, condensation, fumes, and non-grease laden vapors.
Completely enclosed electric convection ovens, microwave ovens,
toasters, coffee makers, steam tables, rice cookers and other equipment that doesn’t create indoor air quality or
sanitation problems are not required to be installed under an exhaust hood. Equipment that meets UL 197
standards do not need to be installed under exhaust hoods, enclosed chicken rotisseries, are an example of this
type of equipment.
ROOM FINISH:
A finish schedule for walls, floors, ceilings and coved juncture base must be provided for food prep areas, dish wash
area, storage and restrooms for Plan Review purposes.
Walls and ceilings shall be light colored, smooth, nonabsorbent and easily cleanable. Food areas with ceiling tile
must have vinyl faced, smooth, non-fissured easily cleanable tiles.
Exposed Concrete Masonry Unit (CMU) walls are acceptable as long as the mortar joints are flush, are thoroughly
sealed and painted with at least two coats of enamel or polyurethane.
FRP panels or other nonabsorbent water resistant wall protection is recommended in dish washing or other wet
areas, such as around mop sinks.
Stainless steel panels should be installed under exhaust hoods, behind cooking equipment.
FOOD
PROTECTION:
Include sneeze guards on
buffets and any other
areas where food might
need protection from
contamination.
BUILD TO KEEP PESTS OUT:
Minimum #16 mesh screens are required on all
operable windows.
Include screen doors on all doors that employees
might be tempted to open for ventilation.
Air curtains are recommended on delivery doors.
Exterior doors and serving windows must be self-
closing.